Unibrain 501 User Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
Unibrain Fire-i 501/511/601/701/702/810 Operation Manual Page 38
3.10.8. Trigger Mode 5
This mode is “multiple shutter pulse width mode”. The camera starts integration of the incoming light from the first
external trigger input falling edge and exposes incoming light until the trigger is inactive. It repeats this sequence for
the N-th (parameter) external trigger input falling edge and then the integration finishes. A Parameter is required and
shall be one or more. (N >= 1)
3.10.9. Trigger Mode 12
Trigger mode 12 is only supported on Fire-i 701/702/810 cameras. The user can capture the multi frame rates with
one trigger signal. The users can control the Gain and Shutter by the Parameter Table which has a range from 1 to 255.
Mode 12 is supported by both H/W trigger and S/W trigger.
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 81 82

Comments to this Manuals